Launching a medical device requires much preparation. As these devices are heavily regulated, a company has to meet many requirements in different phases of the development and manufacturing process. Which phases are there to consider and what are their characteristics? This blog digs deeper into the lifecycle of a medical device and requirements that must be met in those phases.

From idea to post market surveillance: the phases of the medical device lifecycle | QbD Group
5:08

 
 

Ideation and feasibility phase

 

Every medical device invention, from a simple syringe to an advanced CT scanner, starts with an idea. This idea obviously needs research:

  • How feasible is it to develop a successful product?
  • What will be the intended use of the invention? Who will use it?
  • Is it a medical device according to the definitions in the regulations?
  • What risk class is the medical device assigned to?
  • What markets do I want to launch and what will be the regulatory strategy?
  • Are there competitors already?
  • Which investments are required to come up with a successful product?

This research phase ends with the decision to either abandon an idea or to approve it and move on to the next phase: design and development.

 

Design and development phase

 

The goal of the design and development (D&D) phase is to demonstrate that:

  • the device is safe to use
  • the device specifications meet the requirements and the user needs,
  • you will be able to manufacture the newly developed device. 

The complete D&D trajectory should be executed according to a pre-approved D&D plan and all information must be documented in the D&D files (or the Design History File, as FDA calls it).

Therefore, procedures describing the company’s application of the D&D phase are  required. Additionally, other policies, procedures or work instructions may be needed for other determinants of device quality that should be considered during the D&D process.  The need for policies and procedures for these factors is dependent upon the types of devices manufactured by a company and the risks associated with their use. Examples of topics for which procedures may be appropriate are risk management, clinical evaluations, document control, training, configuration management etc.

Therefore, the implementation of a Quality Management System will be required and, in turn, an ISO 13485:2016 certification and the implementation of a Quality Management System is required in most cases(for example Scilife).

As part of the design and development phase, the product will be verified and validated. This part of the process determines if there is objective evidence that both the design inputs (verification) and intended use (validation) are met. This process is mostly supported by tests, , analyses, clinical evaluations or even clinical investigations, and all is documented within the QMS as part of the D&D files.

During the D&D trajectory the design is transferred into suitable production specifications. This design transfer includes among others the development and validation manufacturing processes, trainings,  supplier products specifications and maintenance instructions.

Please note that D&D does not end with the final transfer of a design to production. It still applies to all changes to the device or manufacturing process design, including those occurring long after a device has been introduced to the market. The D&D process can be revisited many times during the lifecycle management of the product, including as a result of post market surveillance feedback for example.

In parallel with the D&D process and prior releasing the new device to the market, the registration process takes place in which a technical file is prepared for submission to the relevant notified body which will take care of certification.

 

Device production and Post Market phase

 

In preparation of this phase, the QMS will be further expanded to guarantee a qualitative launch of the product. For example, as a result of design transfer, a batch release process and QC procedures are put in place. Also event, CAPA, change and complaint management processes need to be set-up and a Post Market Surveillance (PMS) process and a PMS plan specifically for the newly developed Medical Device are required.

Events, such as complaints, can bring new insights and may require controlled changes. Market surveillance and post market clinical follow-up (PMCF) are required not only reactively, but also proactively to ensure the quality, performance, and safety of the device after being released to the market.

The right services at the right time

Throughout the whole process, documenting every aspect of the device and the process is key. For many companies in the medical devices industry, parts of the process are supported by in-house staff and outside experts (like QbD). 

Newcomers in the business can rely on the full scope of our services, starting already in the feasibility phase, throughout post-market activities. 

QbD provides training via the QbD Academy on ISO 13485:2016 and helps starters to create a roadmap to CE certification

In the design and development phase we provide support for all regulatory requirements, including technical documentation, data management statistics, project and site management and compliance and medical writing. 

When it comes to manufacturing, we deliver support for among others process development, equipment qualification, process validation, QA support, and software validation

Finally, QbD has specialists in post-market support.  

 

 

 
 

Stay ahead in life sciences

Keeping up with the fast-paced life sciences industry doesn’t have to be overwhelming.

Our newsletter delivers the latest insights, industry updates, and expert content directly to your inbox, helping you stay informed and make smarter decisions.

Circles-banner-short

Discover more expert content

preview_image
Webinar

From Requirements to Code: a unified MDSW development cycle that covers all requirements

Watch our webinar on demand to master medical device software development. Learn about IEC standards, cybersecurity, AI integration, and FDA expectations.
preview_image
Case study

Ensuring pharmaceutical production quality: cleaning validation for government agency

Discover how QbD Group helped a client tackle dual validation challenges for their production lines, ensuring GMP compliance and AEMPS approval.
preview_image
Webinar

How to manage mandatory communication of Toxicological Risks?

Learn how to effectively manage toxicological risks in the pharmaceutical industry by addressing, reporting, and mitigating potential harm.
preview_image
Webinar

Setting up ATMP Quality Management Systems: Strategies for Compliance and Success

Discover strategies for establishing a compliant and successful ATMP Quality Management System. Watch our webinar on demand.
preview_image
Blog

What Makes Usability Testing Crucial for Near-Patient and Self-Testing Devices under IVDR?

It shouldn’t be a surprise that today, “Near-Patient Testing (NPT)” and...
preview_image
Blog

When does Annex XIV apply in Performance Studies, and what key documentation is needed for compliance?

In the European regulatory landscape, conducting performance studies for in...
preview_image
Blog

How to define your Clinical Performance Strategy?

1. Start with a clear intended purpose A strong clinical...
preview_image
Blog

The Holy Grail: Achieving Inspection Readiness

In a previous blog post, we talked about the various activities...