MDR Certification for Legacy Devices: Integrating Clinical Evidence for Compliance

    MDR Certification for Legacy Devices: Integrating Clinical Evidence for Compliance

    Regulatory Affairs Clinical Medical Devices EU MDR

    Wednesday, 28 February 2024

    person-image

    Sandy Adjemian, Senior Medical Writer at QbD Group

    share-iconshare-icon-mob Share

    X (Twitter) icon\ \ X (Twitter) LinkedIn icon\ \ LinkedIn WhatsApp icon\ \ WhatsApp Copy link icon\ \ Copy link Mail icon\ \ Mail

    Find out what is required to maintain marketing approval for older devices in the EU.

    Play

    MDR Certification for Legacy Devices: Integrating Clinical Evidence for Compliance | QbD Clinical

    AI-generated audio

    9:09

    Medical Devices CE certified under the European Medical Device Directive (MDD) or the Active Implantable Medical Devices Directive (AIMDD), are frequently referred to as legacy devices. Manufacturers face unique challenges when transitioning to compliance with the Medical Device Regulation (MDR) for their legacy devices.

    One critical aspect is determining the level of “sufficient” clinical evidence required for MDR certification, a task even more complicated by the lack of explicit guidance in the MDR. Legacy devices often lack the extensive clinical data required by the MDR.

    In some cases, these legacy devices may have been on the market for many years, with their initial approval based on less rigorous criteria compared to the current MDR standards. This poses a unique challenge in demonstrating conformity with the new regulations.

    In this blog post, we explore the complexities surrounding clinical evidence for legacy devices and shed light on the strategies manufacturers can employ to meet the MDR standards.

    Whitepaper - Clinical evaluation

    Free whitepaper

    Clinical evaluation for medical devices under MDR

    In this whitepaper, we’ll guide you through crucial regulatory documents pertaining to the clinical evaluation process of your medical device.

    Download now

    What is sufficient clinical evidence for legacy devices?

    The MDR aims to enhance the safety and performance of medical devices while ensuring a more transparent and consistent regulatory framework. One of the fundamental shifts introduced by the MDR is the heightened emphasis on clinical evidence to support the safety and performance claims of medical devices.

    The MDR, in Article 61 (1), stipulates that conformity with relevant General Safety and Performance Requirements (GSPR) must be substantiated by clinical data providing sufficient clinical evidence. It is further detailed that the manufacturer shall specify and justify this level of clinical evidence, which should be appropriate given the characteristics of the device and its intended purpose. Manufacturers of legacy devices need to bridge the gap between their existing clinical data and the heightened expectations of the MDR.

    Sources of clinical data

    The Medical Device Coordination Group (MDCG) 2020-6 outlines pre-market and post-market sources of clinical data applicable to legacy devices:

    Pre-market clinical data:

    • Clinical investigation reports of the device in scope.

    • Clinical investigation reports or other studies reported in scientific literature, of an equivalent device (demonstration of equivalence should be according to the MDR).

    • Reports published in peer-reviewed scientific literature on other clinical experiences of the legacy device or an equivalent device.

    • Other pre-market data, e.g., case reports on experience with the use of the device in scope.

    Post-market clinical data:

    In principle, manufacturers of legacy devices should have gathered clinical data from the initial certification under the MDD/AIMDD (pre-CE-mark clinical data), and since they have been on the market for several years, they usually have data collected during the post-market phase as well.

    • Post-Market Surveillance (PMS) clinical data, complaints, and incident reports.
    • Post-Market Clinical Follow-up (PMCF) studies, including post-market clinical investigations.
    • Independent clinical studies using the device.
    • Device registries.
    • Literature-derived data.

    Engaging with direct users of the legacy devices can also provide valuable insights (e.g., through user surveys). Their experiences and feedback can inform the development of targeted studies and contribute to a more comprehensive understanding of the device’s performance in real-world settings.

    Generating New Data

    If post-market data are insufficient, and no equivalence to similar CE-marked medical devices can be claimed, manufacturers might need to generate new data to obtain MDR certification, e.g., by setting up clinical investigations or high-quality surveys, by analyzing real-world evidence or by engaging in other Post Market Follow Up activities.

    Although MDR requires data from clinical investigations held by the manufacturer in general, some exemptions to perform clinical investigations are outlined in MDR Articles 61 (4), 61 (5) and 61 (6), and concern Class III and implantable legacy devices demonstrated to be equivalent to previously marketed devices, legacy devices, and Well-Established Technologies (WET). However, this exemption from clinical investigations is only valid when there is already sufficient clinical data to confirm compliance with the MDR GSPR.

    The case of Well-Established Technologies (WET) and Standard of Care Devices

    As defined in the MDCG 2020-6, Well-Established Technologies (WET) have the following features:

    • Relatively simple, common and stable designs with little evolution.
    • Their generic device group has well-known safety and has not been associated with safety issues in the past.
    • Well-known clinical performance characteristics and their generic device group are standard-of-care devices where there is little evolution in indications and the state of the art.
    • A long history on the market.

    For legacy devices meeting these 4 criteria and considered “standard of care devices”, a lower level of clinical evidence might be acceptable.

    According to MDR Article 61 (6), Class III and implantable legacy devices, as well as a restricted list of well-established technologies (WET), may be exempt from the requirement for clinical investigations provided they have sufficient clinical data. The MDCG Guidance 2023-7 was created to provide guidance on exemptions from the requirements to perform clinical investigations according to article 61(4)-(6) of the MDR and on sufficient levels of access to data needed to justify claims of equivalence (which is outside of the scope of this blog post).

    The list of these WETs is presented in Article 61 (6b) of the MDR and includes among others, sutures, staples, dental fillings, dental braces, and connectors. This defined list of WETs can only be amended by a delegated act (a new legislation) (Article 61 (8)). Manufacturers wanting to place on the market a new device belonging to this group of WETs can do so without performing clinical investigations. Indeed, unlike Class III and implantable legacy devices in general, these WETs do not need a previous certification under the Directives to be exempt from the need to perform clinical investigations.

    Devices suitable for Article 61 (10)

    Some legacy devices might fall under Article 61 (10) of the MDR, for which clinical data is not deemed appropriate. Such devices are, for example, accessories, medical equipment cleaning and sterilization devices, or basic surgical instruments such as forceps. Article 61 (10) is never applicable to Class III and implantable devices.

    For devices meeting Article 61 (10), the demonstration of conformity can be based on non-clinical testing methods only, such as performance evaluation, bench testing and pre-clinical evaluations. For legacy devices, PMS data are also included in the CER.

    As mentioned in MDCG 2020-6 Appendix III, the following types of evidence are relevant for these devices:

    • Compliance with non-clinical elements of common specifications considered relevant to device safety and performance (mechanical testing for strength and endurance, biological safety, usability, etc.).
    • Simulated use, animal, cadaveric testing involving healthcare professionals or other end users (can be used to demonstrate usability for accessories or instruments).
    • Pre-clinical and bench testing, compliance with standards.

    Manufacturers should justify that Article 61 (10) applies to their device, based on risk assessment and management and considering the interaction of the device with the human body. Devices interacting with the human body are not excluded but are less likely to be suited for Article 61 (10).

    All the claims made for a medical device, being clinical or non-clinical, should be supported by data. Clinical claims are claims for which a positive impact on the health of the individual can be measured (clinical benefit). Such clinical claims should be supported by clinical data, and therefore devices with clinical claims are not in the scope of Article 61 (10).

    Non-clinical claims focus on aspects other than direct health outcomes or performance in a clinical setting. Instead, manufacturers might highlight features related to user experience, design, durability, or ease of use, and each of the claims should be supported by appropriate evidence.

    For Article 61 (10) devices, manufacturers should still generate a literature review on their device, as well as a clinical evaluation report (CER) and PMS plan to be reviewed by the Notified Bodies.

    Clinical Evidence Requirements for Legacy Devices Under MDR

    To successfully navigate MDR certification for legacy devices, manufacturers should adopt a strategic approach to address the clinical evidence requirements, taking into account some key considerations.

    Gap Analysis

    A comprehensive gap analysis should be conducted to identify the disparities between existing clinical data and the MDR requirements. This analysis will help manufacturers understand the extent of additional evidence needed for certification.

    Risk Management

    Robust risk management processes can help to identify and mitigate potential risks associated with the device. Clear documentation of risk assessments will strengthen the case for MDR certification.

    Post-Market Surveillance

    Effective post-market surveillance mechanisms should be established to continuously monitor and evaluate the device’s performance and safety in real-world scenarios. This ongoing data collection can contribute to valuable evidence for MDR compliance.

    Literature Reviews and Meta-Analyses

    The existing literature should be explored to supplement the available clinical evidence. This can be especially valuable for legacy devices with limited original clinical data.

    Want to know more? Download our white paper on SOTA literature reviews here.

    Collaboration with Notified Bodies

    By engaging in open communication with Notified Bodies to gain insights into their expectations and interpretations of the MDR requirements, this collaboration can facilitate a smoother certification process. Important to note is that Notified Bodies are not allowed to provide advice on the specific medical device in scope.

    Whitepaper - Clinical evaluation

    Free whitepaper

    Clinical evaluation for medical devices under MDR

    In this whitepaper, we’ll guide you through crucial regulatory documents pertaining to the clinical evaluation process of your medical device.

    Download now

    How can we assist in obtaining MDR certification for your legacy device?

    Navigating MDR certification for legacy devices requires a proactive and strategic approach, with a strong emphasis on generating robust clinical evidence.

    QbD Regulatory can help you to prepare the Technical Documentation, including risk management and post-market surveillance documents.

    QbD Clinical Medical Writing specializes in performing the required clinical evaluation for your device, including addressing the possible gaps in clinical evidence for your device in scope. This involves reviewing and analyzing all necessary literature and writing the clinical evaluation plan and report. These documents are created following all applicable guidance and regulations.

    Our involvement has already aided several medical device manufacturers in obtaining a CE certificate for their devices in 2023. This success was achieved without any comments from Notified Bodies and Regulatory Authorities, despite the additional scrutiny from expert panels via the EU Commission or MDCG and the extended timelines.

    Don’t hesitate to reach out to us for assistance, whether it is coaching, reviewing, or fully writing your technical documentation as required.

    Need regulatory support?

    Trust our expertise to guide you through the regulatory process and achieve compliance

    with ease.

    Discover how we can help.

    Read more

    Stay ahead in life sciences

    Keeping up with the fast-paced life sciences industry doesn’t have to be overwhelming.

    Our newsletter delivers the latest insights, industry updates, and expert content directly to your inbox, helping you stay informed and make smarter decisions.

    Subscribe to our newsletter

    Circles-banner-short

    Discover more expert content

    preview_image

    Webinar

    AI in Life Sciences

    Join our webinar with delaware on implementing compliant AI in life sciences. Learn best practices and avoid pitfalls in GxP environments from industry experts. Register now.

    Read More

    preview_image

    Webinar

    From R&D to market IP and regulatory strategy across the product life cycle

    Join this Biovia x Gevers x QbD Group webinar to explore product life cycle strategies, focusing on R&D, regulatory alignment, and Quality by Design insights for life sciences professionals.

    Read More

    preview_image

    Webinar

    Fast GxP compliance: Accelerating Digital Transformation in Life Sciences

    QbD Group and delaware are combining their expertise to deliver a powerful webinar on how to implement and validate SAP efficiently, without compromising on compliance. You don't want to miss it!

    Read More

    preview_image

    Whitepaper

    The Essential CSV & Digitalization FAQ for Life Sciences Companies

    Get clear answers to real CSV questions from clients & experts. Download our FAQ and stay compliant, audit-ready, and confident in your Software Validation Strategy.

    Read More

    preview_image

    Whitepaper

    Audit Trail Review in GxP Environments

    Learn how to implement a risk-based Audit Trail review strategy to enhance software compliance in GxP environments.

    Read More

    preview_image

    Case study

    Fast-Tracked Site Qualification for Clinical Trial Submission

    QbD Group helped a biotech company complete 5 site qualification visits in just 3 weeks enabling a timely and compliant clinical trial submission.

    Read More

    preview_image

    Whitepaper

    Digital Health - Exploring the landscape and future opportunities

    This whitepaper informs you about digital health, key technology pillars, and new opportunities to anticipate future trends in your healthcare sector.

    Read More

    preview_image

    Whitepaper

    A Complete Guide to Computer System Validation

    This guide aims to bring context and define the necessary and appropriate strategies for the validation of computerized systems. Download now.

    Read More

    preview_image

    Whitepaper

    ISO 13485:2016 - Compliance Checklist

    Are you up to date with the latest medical device QMS requirements? Download our free ISO 13485:2016 checklist to ensure compliance.

    Read More

    preview_image

    Case study

    Enhancing data integrity & aseptic manufacturing compliance

    QbD Group helped a leading medical tech company improve MDR compliance and enhance aseptic manufacturing for long-term regulatory readiness.

    Read More

    preview_image

    Whitepaper

    Medical Device Regulation (MDR) Checklist

    Implement the Medical Device Regulation (MDR) with ease. Download our checklist of mandatory documents for MDR compliance.

    Read More

    preview_image

    Webinar

    Evidence Throughout the Lifecycle: Integrating Clinical Needs into Design & Documentation

    Discover how to integrate clinical needs into medical device software design to meet MDR requirements. Watch our webinar on demand.

    Read More

    preview_image

    Whitepaper

    Clinical Evaluation for Medical Devices under MDR

    This whitepaper will guide you through crucial regulatory documents pertaining to the clinical evaluation process of your medical device. Download now!

    Read More

    preview_image

    Webinar

    From Concept to Market: Comprehensive Market Access Strategies for Medical Device Software

    Learn how to launch your Medical Device Software successfully with expert insights on market access and commercialization strategies. Watch our webinar on demand.

    Read More

    preview_image

    Whitepaper

    State-of-the-art literature review: kick off the Clinical Evaluation of your Medical Device

    This whitepaper will walk you through the steps of conducting solid systematic SOTA literature searches for your clinical evaluation. Download now.

    Read More

    preview_image

    Webinar

    Drug-Device Combination Products and Article 117

    Explore the regulatory complexities of Drug-Device Combination Products. Learn about Article 117 requirements, Notified Body Opinions, and more.

    Read More

    preview_image

    Whitepaper

    Mobile health on the rise: exploring the regulatory landscape for reimbursement

    This whitepaper will help you navigate the maze of the DTx regulatory environment, highlighting several important countries and regulations.

    Read More

    preview_image

    Whitepaper

    The pathway from idea to patient under MDR

    This guide explains the pathway and steps needed to test your device in human subjects, aiming to get your product to market. Download now.

    Read More

    preview_image

    Whitepaper

    Clinical investigations under MDR: key insights and practical experiences

    This whitepaper covers clinical investigation authorization under MDR, the EU Legal Representative's role, and the MDR's impact on study conduct and post-market surveillance.

    Read More

    preview_image

    Case study

    CE Mark Renewal for bioXtra Products: A Success Story

    Discover how Lifestream Pharma successfully renewed the CE mark for their BioXtra Dry Mouth products under the EU MDR. Learn about the challenges faced, the approach taken for compliance, and the results achieved.

    Read More

    preview_image

    Webinar

    Technical Documentation Essentials for Medical Device Software

    Gain practical insights on crafting MDR-compliant technical documentation for Medical Device Software.

    Read More

    preview_image

    Webinar

    Getting Started: Overcoming Initial Obstacles in Medical Device Software Development

    Watch our webinar on demand and learn about regulatory obstacles, MDR, AI Act, and best practices for medical device software development and market entry.

    Read More

    preview_image

    Whitepaper

    GAMP 5 Software Validation Approach for GMP, GCP and GLP regulations

    Learn how to comply with GMP, GCP, and GLP regulations using the GAMP 5 Software Validation Approach. Download the whitepaper for more insights.

    Read More

    preview_image

    Whitepaper

    Standards and regulations for software used in Medical Devices

    Explore the essential standards and regulations for software used in Medical Devices, including IEC 62304 and IEC 82304. Download now.

    Read More

    preview_image

    Webinar

    Post-Market Surveillance Requirements for Medical Devices and IVDs

    Learn about post-market surveillance requirements under MDR and IVDR regulations. Gain insights from industry experts in this on-demand webinar.

    Read More

    preview_image

    Whitepaper

    21 CFR Part 11 compliance checklist

    Want to assess whether a computer system generates electronic records and uses electronic signatures, and whether the system complies with Part 11 of 21 CFR? Download this free checklist.

    Read More

    preview_image

    Webinar

    Second edition of GAMP 5: A Risk-Based Approach to compliant GxP Computerized Systems

    This webinar on demand will tell you more about the second edition of GAMP 5.

    Read More

    preview_image

    Webinar

    Verification & Validation of Artificial Intelligence/ Machine Learning Medical Devices

    Explore the impact of Artificial Intelligence and Machine Learning on medical device validation and verification processes.

    Read More

    preview_image

    Whitepaper

    GAMP categories for computerized systems: what are they and what are they for?

    In this whitepaper, you will learn what GAMP is, what GAMP categories are for, and where to start if you are facing computerized systems validation.

    Read More

    preview_image

    Webinar

    3D Printing in the Healthcare World

    Explore the challenges and opportunities of 3D printing in healthcare, featuring expert insights on regulations, pitfalls, and efficiency.

    Read More

    preview_image

    Whitepaper

    EUDRALEX Volume 4 Annex 11 Compliance Checklist

    Assess your computer system's compliance with EudraLex Volume 4 Annex 11 guidelines using our checklist. Download now for GMP assurance.

    Read More

    preview_image

    Whitepaper

    From V-model to Agile: how to embrace automation as part of the computerized system validation approach

    This white paper explores why IT is shifting to agile, focuses on the prevalent Scrum methodology, and concludes with guidance on adapting system validation processes.

    Read More

    preview_image

    Case study

    Ensuring a smooth MDR transition for Oystershell's medical devices

    The landscape of medical device regulations is constantly evolving, making it a challenge for companies to keep up. Our collaboration with Oystershell, which began in July 2023, highlights our expertise in transforming complex challenges into success stories, all with a touch of QbD Clinical magic.

    Read More

    preview_image

    Case study

    Successful clinical evaluation supports rapid CE marking of Minze Health's Uroflowmeter

    QbD Clinical assisted Minze Health, a urology-focused medical devices company, in obtaining CE marking under MDR through clinical evaluation.

    Read More

    preview_image

    Webinar

    The Medical Device CE Certification Pathway Explained: From Classification to Conformity Assessment by the Notified Body

    Learn about the Medical Device CE Certification Pathway, from classification to conformity assessment by a Notified Body. Join our webinar on demand.

    Read More

    preview_image

    Case study

    Helping Relu to comply with changing regulations

    QbD Group supported software company Relu with their expertise to comply with changing regulations.

    Read More

    preview_image

    Case study

    Helping Abraca BioSystems to obtain ISO 13485 certification

    QbD Group helped Abraca Biosystem gain entry into the MD/IVD industry by supporting them on their path to ISO 13485 certification.

    Read More

    preview_image

    Case study

    Help BioLizard build their Quality Management System

    QbD Group helped BioLizard document the fundamental processes of their QMS and enabled them to continue building it on their own.

    Read More

    preview_image

    Case study

    Supporting Oncomfort in developing and certifying their ISO 13485 QMS

    QbD Group helped Oncomfort quickly implement and certify an ISO 13485 compliant Quality Management System.

    Read More

    preview_image

    Case study

    Quickly bringing a new COVID-19 medical device to market

    Obtaining the required government certifications for a medical device is always a challenge. Especially when the COVID clock is ticking.

    Read More

    Discover all

    Twitter Widget Iframe